Ultrasound Therapy Physiotherapy 1&3 Mhz Machine LCD preset program Machine
$ 250.8
- Description
- Size Guide
Description
We sell only Quality EquipmentDon't buy any product from non-professional Company
We are professional company deals in Healthcare equipment for the last 18 years.
Pain free… Stress free… On the Road to Faster Recovery
Revolutionary Devices in Pain Management and Rehabilitation
Limited time offer, don't miss it....
Professional use Ultrasound therapy device
1 & 3 Mhz Frequency
Pre-programmed and LCD Display
Model : BT 05002
Light weight transducer
Auto detection of Ultrasound applicator
FEATURES:
Microprocessor controlled Digital Unit
Pulsed and Continuous therapy operation 10%, 20%, 50% and 100%
Veriable duty cycle output of 16 Hz, 48 Hz, or 100 Hz.
Clinical protocols, the most appropriate application and parameter set for the patient’s condition.
Iight weight designs for Clinic, Hospital and Home visits.
Auto detection of Ultrasound applicator.
Micro controller based design for optimum accuracy.
Soft touch buttons.
Timer : 0-30 min
put power is up to 2.5 watts / cm2, which is controlled digitally
Back light LCD display
TECHNICAL SPECIFICATION:
Frequency : 1 & 3 MHz
Ultrasound Output : 15 Acoustic
Ultrasound Head : 2.5watts/cm2
Modes: continuous and pulse waves.
Available voltage: 220v
(For USA and Canada buyer, we will provide voltage converter free of cost)
ACCESSORIES :
Main Unit : 01 No.
Ultrasound Applicator :02 Nos. (1 for 1 Mhz & 1 for 3 Mhz)
Power socket /Cord provided for different countries :01 No.
Instruction Manual :01 No
Carry Bag :01 No.
APPLICATION:
Therapeutic Ultrasound provides therapeutic deep heat treatment for
Relaxation
Reduce swelling and inflammation.
Promote the synthesis of proteins inside the cells
Lymphatic Drainage with cellulite reduction
Regenerate wounded tissues
Accelerate the metabolism of cells
Preset Ultrasound Programmes:
Micro controller based ULTRA-SOUND contains 100 programmes, which are divided into following manners:
Prg. 1-32 are set programmes (With all parameter set except, Power Level which varies from 0.0 to 2.5W/cm sq )
Prg. 33-80 are Blank programmes. (Company upgradation pro.)
Prg. 80-89 are User defined programmes.
List of Clinical Program
Cervical, Mus. Spam, Acute 3MHz
Cervical, Mus. Spam, Sub acute 3MHz
Cervical, Mus. Spam, Chronic 3MHz
Cervical Mus. Strn., Acute 3MHz
Cervical, Mus. Stm., Sub acute 3MHz
Cervical, Mus. Stm., Chronic 3MHz
Cervical, Nrv. Root IMHz
Thoracic, Mps. Spam, Acute 1MHz
Thoracic, Mus. Spam, Sub acute 1MHz
Thoracic, Mus. Spam, Chronic 1MHz
Thoracic, Mus. Stm., Acute 1MHz
Thoracic, Mus. Stm., Sub acute 1MHz
Thoracic, Mus. Stm., Chronic I MHz
Lumber, Mus. Spam, Acute 1MHz
Lumber, Mus. Spam„Sub acute I MHz
Lumber, Mus. Spam, Chronic 1MHz
Lumber, Mus. Stm., Acute I MHz
Lumber, Mus. Stm., Sub acute 1MHz
Lumber, Mus. Stm., Chronic 1MHz
Lumber, Nrv. Root . 1/v1Hz
Shoulder,Bicip Tendon, Acute 1MHz
Shoulder,Bieip Tendon, Sub acute 1MHz
Shoulder,Bicip Tendon, Chronic 1MHz
Shoulder, Bursitis, Acute 1MHz
Shoulder, Bursitis, Sub acute 1MHz
Shoulder, Rot. Cuff Acute 3MHz
Shoulder, Rot. Cuff, Sub acute 3MHz
Shoulder, Rot. Cuff Chronic 3MHz
Elbow, Olecrunon, Acute 3MHz
Elbow, Olecrunon, Sub acute 3MHz
Elbow, Lateral, Acute 3MHz
Elbow, Lateral, Sub acute 3MHz
INDICATION( Continuous/ Pulsed )
Continuous output is preferable for following indications
Chronic Neuromata
Myalgia
Sudek”s syndrome
Tethered scar tissue- This should be treated as early as possible & the increased circulations etc. frees the scars if very localized then it should be pulsed ultrasound.
Pulse output is preferable for following indications.
Severe sprain & strains of muscle fibers, tendons & ligaments-Previously these used to take weeks to geta full functions but with ultrasound now takes days.
Crushed hands or feet- the immediate use of ultrasonic therapy prevents the formation of fibrous tissue, by the absorption the free blood etc, making the early restoration of function possible when the fracture allow.
Dislocation of fractures into or near joints- these too should be treated immediately to prevent adhesions forming as the result of unabsorbed free fluids.
Haematoma from severe muscle tears & haemarthrosis from trauma or haemophilia the quick absorption of free blood is essential for speedy restoration of function.
Acute tenosynovitis, tendonitis, de quevain” s stenopsing tendo- vaginities etc. quick recovery
Acute synovitis or capsulitis quick recovery
Carpul tunnel syndrome often effective
Reticular nerve pains i.e. Brachial neuritis, intercostalis neuritis lumbago, sciatica etc. pulsed ultrasound given to the appropriate nerve roots gives immediate reduction in pain.
Herpes Zostar- the residual nerve pains is greatly reduced in about 50% of the patients.
Anldyosing spondylitis most effective in early stages, reduces pain & increase mobility. This progressive disease can be kept at a very slow face of progression if repeated courses of treatment are given .
Scar tissue - early treatment prevents keloid scare formation and softness existing new scars.
Neuromata- it is new scar formation This pain will be completely stopped.
Order safe item from us:
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for
REFERENCE:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
(Payment Details )
Payment is accepted by
Paypal
only. Paypal is the
Safest
mode of
Payment on
e
B
a
y
.
(Shipping Details)
We ship anywhere in world within a
short time
on high priority basis. (We ship the products through
DHL courier
/
Express Post Parcel
which reach to customer within 6-10 days.) Where EMS service will not available from India then we will ship the product through Reg. Post Parcel
.
Taxes, Customs & Duties
We don't add
taxes, VAT or other hidden charges. You pay us what you see on the invoice, i.e. goods subtotal + shipping cost (not include duties) or you may kindly give us some suggestions about that, we promise to do our best to help you! Any custom duty /Vat at destination applicable that will be on customer a/c only.
We will make you sure that you will receive the product in
Good Condition
(Contact Detail)
For any further information plz mail us on
can contact me through eBay by
" Ask Seller A Question
"
(FeedBack)
Your *feedback is important for us to grow our business on eBay, so please do leave feedback,
*Thank you.*
dpk 10/3